Solar panel cost in Torridge (EX39)

See realistic solar installation costs, savings and payback for EX39 (Torridge) in under a minute using official UK data. Start with the calculator, then get a no-obligation quote from an MCS-certified installer. You can also ask the SolarByPostcode assistant to sanity-check your roof, bills and plans.

Solar Calculator

Change the settings below to see how costs and savings work for your situation.

System Size

Roof Direction

Battery Storage

Export Value

Your Numbers

Break-even
9.7 years
After this, it's pure profit
Upfront Cost
£8,139
What you pay to get started
Annual Benefit
£837
What you save every year
Profit Over 25 Years
£12,778
After paying itself off, you're this much ahead

Ready to Get Started?

Get your free quote from Blue Ape Renewables. They'll connect you with MCS-certified installers in your area and handle all the paperwork.

Get Solar Quote →
4.8★ Trustpilot • Octopus Energy trusted partner • MCS certified • No obligation
How we calculate this

Solar generation: Based on typical south-facing roof at 35° angle. We account for weather, dirt, and system losses (14%).

How much you'll use directly:

  • Without battery: You'll use about 40% of what you generate. The rest gets sold back to the grid.
  • With 5 kWh battery: You'll use about 70% (battery stores extra for evening use).
  • With 10 kWh battery: You'll use about 75% (more storage means less exported).
  • Panel-only payback: The official cost per kW is lower above 4 kW, so a 5–6 kW system can pay back a little faster than a 3–4 kW system on otherwise identical assumptions.
  • Battery & payback: Batteries raise self-use and cut bills, but added hardware cost often lengthens break-even at typical UK rates.
  • When a battery can still make sense:
    • Evening-heavy usage patterns
    • Time-of-use tariffs / cheap night rates
    • Low export rate vs. high unit rate
    • Heat pump or EV charging synergy
    • Optional backup/resilience (system-dependent)
    • Lower evening-hour CO₂ vs. grid

Panel costs: Uses March 2026 TIC mean installation costs: £1,827/kW up to 4 kW and £1,628/kW above 4 kW.

Other costs: Battery prices are modelled at £700 per kWh. Export tariffs vary by supplier (usually 5–15p per kWh).

Grid connection: Systems up to about 3.7 kW typically need just a notification (G98). Larger systems may need permission (G99).

These are typical values based on average usage patterns. Your actual results will vary based on your roof, shading, and how you use electricity.

Your area in context

Read the full story

A typical roof here lands around 5.0 kW, with most eligible homes comfortably fitting within 3–6 kW. Each kilowatt of panels produces roughly 1011 kWh per year on a south-facing roof. We value self-used electricity at 26.4p and exported surplus at a baseline 10p via SEG. Use the calculator above for your exact tariff.

Unit rate
26.4p/kWh
Standing charge
57.9p/day
Sunshine yield (south)
1011 kWh/kW
Export price (baseline)
10p/kWh

Browse the scenarios below. Each battery size has its own expand — open the one that matches your plan (or just explore). For each system size (2–8 kW) we show annual output, how much you use directly, what gets exported, annual benefit, upfront cost, break-even, and a 20-year net. Negative numbers are possible — that’s the honest trade-off when adding more battery than your usage profile justifies.

No battery 5 kW example → Annual benefit: £837, Upfront: £8,139, Break-even: 9.7 yrs
System Annual output Self-use Exported Bill saving Export income Annual benefit Upfront cost Break-even 20-year net
2 kW 2021 kWh 809 kWh 1213 kWh £213 £121 £335 £3,256 9.7 yrs £3,438
3 kW 3032 kWh 1213 kWh 1819 kWh £320 £182 £502 £4,883 9.7 yrs £5,157
4 kW 4043 kWh 1617 kWh 2426 kWh £427 £243 £669 £6,511 9.7 yrs £6,876
5 kW 5054 kWh 2021 kWh 3032 kWh £533 £303 £837 £8,139 9.7 yrs £8,595
6 kW 6064 kWh 2426 kWh 3639 kWh £640 £364 £1,004 £9,767 9.7 yrs £10,314
7 kW 7075 kWh 2830 kWh 4245 kWh £747 £425 £1,171 £11,394 9.7 yrs £12,033
8 kW 8086 kWh 3234 kWh 4851 kWh £854 £485 £1,339 £13,022 9.7 yrs £13,751

Assumptions: south-facing, sensible tilt; self-use shares from site rules; export at 10p baseline. Costs: panels £/kW = 1,628, battery £/kWh = 700.

3 kWh battery 5 kW example → Annual benefit: £1,002, Upfront: £10,239, Break-even: 10.2 yrs
System Annual output Self-use Exported Bill saving Export income Annual benefit Upfront cost Break-even 20-year net
2 kW 2021 kWh 1213 kWh 809 kWh £320 £81 £401 £5,356 13.4 yrs £2,663
3 kW 3032 kWh 1819 kWh 1213 kWh £480 £121 £601 £6,983 11.6 yrs £5,045
4 kW 4043 kWh 2426 kWh 1617 kWh £640 £162 £802 £8,611 10.7 yrs £7,426
5 kW 5054 kWh 3032 kWh 2021 kWh £800 £202 £1,002 £10,239 10.2 yrs £9,808
6 kW 6064 kWh 3639 kWh 2426 kWh £960 £243 £1,203 £11,867 9.9 yrs £12,189
7 kW 7075 kWh 4245 kWh 2830 kWh £1,120 £283 £1,403 £13,494 9.6 yrs £14,571
8 kW 8086 kWh 4851 kWh 3234 kWh £1,280 £323 £1,604 £15,122 9.4 yrs £16,953

Assumptions: south-facing, sensible tilt; self-use shares from site rules; export at 10p baseline. Costs: panels £/kW = 1,628, battery £/kWh = 700.

5 kWh battery 5 kW example → Annual benefit: £1,085, Upfront: £11,639, Break-even: 10.7 yrs
System Annual output Self-use Exported Bill saving Export income Annual benefit Upfront cost Break-even 20-year net
2 kW 2021 kWh 1415 kWh 606 kWh £373 £61 £434 £6,756 15.6 yrs £1,926
3 kW 3032 kWh 2123 kWh 910 kWh £560 £91 £651 £8,383 12.9 yrs £4,639
4 kW 4043 kWh 2830 kWh 1213 kWh £747 £121 £868 £10,011 11.5 yrs £7,352
5 kW 5054 kWh 3538 kWh 1516 kWh £934 £152 £1,085 £11,639 10.7 yrs £10,064
6 kW 6064 kWh 4245 kWh 1819 kWh £1,120 £182 £1,302 £13,267 10.2 yrs £12,777
7 kW 7075 kWh 4953 kWh 2123 kWh £1,307 £212 £1,519 £14,894 9.8 yrs £15,490
8 kW 8086 kWh 5660 kWh 2426 kWh £1,494 £243 £1,736 £16,522 9.5 yrs £18,203

Assumptions: south-facing, sensible tilt; self-use shares from site rules; export at 10p baseline. Costs: panels £/kW = 1,628, battery £/kWh = 700.

7.5 kWh battery 5 kW example → Annual benefit: £1,110, Upfront: £13,389, Break-even: 12.1 yrs
System Annual output Self-use Exported Bill saving Export income Annual benefit Upfront cost Break-even 20-year net
2 kW 2021 kWh 1476 kWh 546 kWh £389 £55 £444 £8,506 19.2 yrs £375
3 kW 3032 kWh 2213 kWh 819 kWh £584 £82 £666 £10,133 15.2 yrs £3,187
4 kW 4043 kWh 2951 kWh 1092 kWh £779 £109 £888 £11,761 13.2 yrs £5,999
5 kW 5054 kWh 3689 kWh 1364 kWh £974 £136 £1,110 £13,389 12.1 yrs £8,811
6 kW 6064 kWh 4427 kWh 1637 kWh £1,168 £164 £1,332 £15,017 11.3 yrs £11,624
7 kW 7075 kWh 5165 kWh 1910 kWh £1,363 £191 £1,554 £16,644 10.7 yrs £14,436
8 kW 8086 kWh 5903 kWh 2183 kWh £1,558 £218 £1,776 £18,272 10.3 yrs £17,248

Assumptions: south-facing, sensible tilt; self-use shares from site rules; export at 10p baseline. Costs: panels £/kW = 1,628, battery £/kWh = 700.

10 kWh battery 5 kW example → Annual benefit: £1,127, Upfront: £15,139, Break-even: 13.4 yrs
System Annual output Self-use Exported Bill saving Export income Annual benefit Upfront cost Break-even 20-year net
2 kW 2021 kWh 1516 kWh 505 kWh £400 £51 £451 £10,256 22.8 yrs £-1,243
3 kW 3032 kWh 2274 kWh 758 kWh £600 £76 £676 £11,883 17.6 yrs £1,636
4 kW 4043 kWh 3032 kWh 1011 kWh £800 £101 £901 £13,511 15.0 yrs £4,514
5 kW 5054 kWh 3790 kWh 1263 kWh £1,000 £126 £1,127 £15,139 13.4 yrs £7,393
6 kW 6064 kWh 4548 kWh 1516 kWh £1,200 £152 £1,352 £16,767 12.4 yrs £10,271
7 kW 7075 kWh 5306 kWh 1769 kWh £1,400 £177 £1,577 £18,394 11.7 yrs £13,150
8 kW 8086 kWh 6064 kWh 2021 kWh £1,600 £202 £1,803 £20,022 11.1 yrs £16,028

Assumptions: south-facing, sensible tilt; self-use shares from site rules; export at 10p baseline. Costs: panels £/kW = 1,628, battery £/kWh = 700.

13.5 kWh battery 5 kW example → Annual benefit: £1,143, Upfront: £17,589, Break-even: 15.4 yrs
System Annual output Self-use Exported Bill saving Export income Annual benefit Upfront cost Break-even 20-year net
2 kW 2021 kWh 1557 kWh 465 kWh £411 £46 £457 £12,706 27.8 yrs £-3,560
3 kW 3032 kWh 2335 kWh 697 kWh £616 £70 £686 £14,333 20.9 yrs £-616
4 kW 4043 kWh 3113 kWh 930 kWh £822 £93 £915 £15,961 17.5 yrs £2,329
5 kW 5054 kWh 3891 kWh 1162 kWh £1,027 £116 £1,143 £17,589 15.4 yrs £5,274
6 kW 6064 kWh 4670 kWh 1395 kWh £1,232 £139 £1,372 £19,217 14.0 yrs £8,219
7 kW 7075 kWh 5448 kWh 1627 kWh £1,438 £163 £1,600 £20,844 13.0 yrs £11,164
8 kW 8086 kWh 6226 kWh 1860 kWh £1,643 £186 £1,829 £22,472 12.3 yrs £14,108

Assumptions: south-facing, sensible tilt; self-use shares from site rules; export at 10p baseline. Costs: panels £/kW = 1,628, battery £/kWh = 700.

Figures are illustrative and use the same method as the calculator above. For exact results, adjust your roof direction, tariff, and usage in the calculator.

Before you request quotes in Torridge

Use the numbers above to sanity-check installer quotes. The main things to compare are system size, battery assumptions, payback claims, MCS certification, DNO paperwork and export assumptions.

New quote check

Want a quote sanity check for EX39?

Share the first part of your postcode and a few basics. We’ll help you check whether system size, battery, export and paperwork assumptions look sensible before you commit to installer conversations.

This is a practical sanity-check request, not an instant quote promise. The Blue Ape quote route above remains available if you already want installer introductions.

Request a quote sanity check →

Seasonal solar output in EX39

Monthly generation per kilowatt of solar panels

kWh 36 Jan 55 Feb 89 Mar 119 Apr 128 May 122 Jun 122 Jul 110 Aug 92 Sep 66 Oct 41 Nov 31 Dec
Best month Worst month Winter (Dec–Feb) Other months

Winter output: 48.5% of an average month (Dec–Feb)

Best / worst month: May / Dec

These figures show output per kilowatt (kW) of panels installed. In winter, a 1 kW system here produces about 41 kWh per month; the average month produces around 84 kWh. So a typical 4 kW home system would generate roughly 164 kWh in winter, or 337 kWh in an average month.

Your Area at a Glance

Your Electricity Rate
26.39p/kWh
Daily Fixed Charge
57.89p/day
Local Sunshine
1011kWh/kW
A 1 kW system generates ~1011 kWh per year. A typical home uses ~2,700 kWh per year.
Typical System Size
5.0kW
For houses & bungalows in this area

Local Property Data

Property Types

Houses: 64% • Flats: 16% • Bungalows: 18% Based on 13,041 properties

Coverage

Torridge (95%)|North Devon (5%)

Areas Covered

Bideford North, Hartland, Appledore, Northam, Bideford East, Monkleigh & Putford, Westward Ho!, Bideford South + 3 more

Data Sources & Assumptions

Solar yield: PVGIS (EU Joint Research Centre), January 2025 data

Electricity rates: Ofgem price cap, Q3 2026

Installation costs: DESNZ/MCS data, March 2026 (TIC)

Property data: EPC open data (Open Government Licence), aggregated

All estimates are typical values. Actual results vary based on your specific situation, roof characteristics, and usage patterns.